 Automatic display of internal values	[0 63]
 Meaning of logic input 1	[-1 63]
 Meaning of logic input 2	[-1 63]
 Meaning of logic input 3	[-1 63]
 Meaning of logic input 4	[-1 63]
 Meaning of logic input 5	[-1 63]
 Meaning of logic input 6	[-1 63]
 Meaning of logic input 7	[-1 63]
 Meaning of logic input 8	[-1 63]
 Frequency input setting:0= analog;1= digital encoder; 2=digital f/s;  3=digital f/s 1 edge	[0 3]
 Meaning of logic output 1	[-32 31]
 Meaning of logic output 2	[-32 31]
 Meaning of logic output 3	[-32 31]
 Meaning of logic output 4	[-32 31]
 Choose TRIGGER type 0   inputs 1= 1st alarm  2...63= analog value	[-31 63]
 Meaning of programmable analog output 1	[-63 64]
 Meaning of programmable analog output 2	[-63 64]
 Meaning of 14 bit analog input A.I.1 0= speed ref. 1= torque ref. 2= torque limit ref.	[0 2]
 Meaning of analog input A.I.2 14 bit0= speed ref. 1= torque ref. 2= torque limit ref.	[0 2]
 Meaning of analog input A.I.3 14 bit0= speed ref. 1= torque ref. 2= torque limit ref.	[0 2]
 Load final digital potentiometer reference value	[0.1]
 Run software	[0.1]
 Enable 14 bit analog reference value A.I.1 	[0.1]
 Enable 14 bit analog reference value A.I.2 	[0.1]
 Enable JOG digital speed reference value (P7)  	[0.1]
 Enable digital potentiometer speed reference value	[0.1]
 Enable linear ramp 	[0.1]
 Rounded ramp	[0.1]
 Stop with minimum speed	[0.1]
 Drive software enable	[0.1]
 Reset  alarms	[0.1]
 Enable 14 bit analog reference value A.I.3	[0.1]
 Motor thermal switch ' Block drive ?	[0.1]
 Choose thermal curve	[0 3]
 Managing mains failure 	[]
 0 = trying to work;  1 = recovery;  2= free;  3= emergency brake	[0 3]
 Automatic alarm reset when mains back on	[0.1]
 Invert reference signal software	[0.1]
 Enable soft start 	[0.1]
 Enable flux weakening	[0.1]
 Choose pulses\rev. FREQUENCY INPUT 	[09]
 Enable 16 bit analog speed reference value - if present	[0.1]
 Enable sensor and motor phase tests	[0.1]
 Enable auto-tunings	[0 3]
 Enable frequency speed reference value	[0.1]
 Reset alarm counters and save serial number 	[0.1]
 Rectification bridge 0 = diodes         1 = semicontrolled	[0.1]
 Enable motor  thermal probe management (PT100/PTC/NTC)	[0 3]
 Enable smart brake	[0.1] 
 NOT USED
 Configuration CAN Bus BAUD RATE 0=1M 1=800K 2=500K 3=250K 4=125K 5=50K 6=20K 7=10K [07]
 Choose zero phase for SIMULATED ENCODER	[03]
 Invert channel B SIMULATED ENCODER	[0.1]
 Choose pulses\rev. SIMULATED ENCODER	[011]
 Enable FIELD-BUS reference values	[0.1]
 Enable locked RUN	[0.1]
 Incremental or Absolute Simulated Encoder	[0,1]
 Type of overload 0=120% 30 ; 1=150%  30"; 2=200%  30 ; 3=200%  3 +155% 30 	[0 3]
 Enable radiator heat probe management (PTC/NTC) 	[0.1]
 Reset CAPTURE monitor	[0.1]
 Disable dynamic decoupling + feedfoward  	[0.1]
 Parameter bank active	[0.1]
 Read default parameters	[0.1]
 Read parameters from permanent memory	[0.1]
 Save parameters in permanent memory (FLASH)	[0.1]
 Enable current control	[]
 Enable overlapped space loop 	[0.1]
 Intervention edge monitor TRIGGER 0 = up;  1= down	[0.1]
 Resolver carrier frequency	[-3,3]
 Enable Sin/Cos Encoder auto-tuning	[0.1]
 Enable 2nd order filter on speed regulator	[0.1]
 Enable frequency speed reference value decoded in time	[0.1]
 Enable theta_precision by-pass 	[0.1]
 Enable Braking Resistance Thermal Protection 	[0.1]
 Enable Safety STOP only like signaling	[0.1]
 Enable Incremental Encoder Time Decode	[0.1]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]    