 Automatic display of internal values	[063]
 Meaning of logic input 1	[-163]
 Meaning of logic input 2	[-163]
 Meaning of logic input 3	[-163]
 Meaning of logic input 4	[-163]
 Meaning of logic input 5	[-163]
 Meaning of logic input 6	[-163]
 Meaning of logic input 7	[-163]
 Meaning of logic input 8	[-163]
 Frequency input setting: 1 = digital encoder; 2=digital f/s 	[12]
 Meaning of logic output 1	[-3231]
 Meaning of logic output 2	[-3231]
 Meaning of logic output 3	[-3231]
 Meaning of logic output 4	[-3231]
 Choose TRIGGER type 0   inputs 1 = 1st alarm 2...63= analog value	[-3163]
 Meaning of programmable analog output 1	[-6364]
 Meaning of programmable analog output 2	[-6364]
 Meaning of 14 bit analog input A.I.1 0= freq. ref.1= tor. ref. 2= torque lim. ref.	[02]
 Meaning of analog input A.I.2 14 bit 0= freq. ref.1= tor. ref. 2= torque lim. ref.	[02]
 Meaning of analog input A.I.3 14 bit 0= freq. ref.1= tor. ref. 2= torque lim. ref.	[02]
 Load final digital potentiometer reference value	[0.1]
 Run software	[0.1]
 Enable 14 bit analog reference value A.I.1 	 [0.1]
 Enable 14 bit analog reference value A.I.2 	[0.1]
 Enable JOG digital frequency reference value (P7)  	[0.1]
 Enable digital potentiometer frequency reference value	[0.1]
 Enable linear ramp 	[0.1]
 Rounded ramp	[0.1]
 Stop with minimum speed	[0.1]
 Drive software enable	[0.1]
 Reset  alarms	[0.1]
 Enable 14 bit analog reference value A.I.3	[0.1]
 Motor thermal switch ' Block drive ?	[0.1]
 Choose thermal curve	[03]
 Managing mains failure 0 = trying to work; 1 = recovery; 2= free; 3= emergency brake	[03]
 Automatic alarm reset when mains back on	[0.1]
 Invert reference signal software	[0.1]
 Enable power soft start 	[0.1]
 Enable frequency dead-zones 	
 0 = disable;  1 = zone 1 ;  2= zone 1 and 2	[02]
 Choose pulses\rev. FREQUENCY INPUT 	[09]
 Enable that drive in current or torque limit for a long time causes stall alarm A7 	[0.1]
 NOT USED	[]
 Enable auto-tuning	[0 1]
 Enable frequency reference in frequency 	[0.1]
 Reset alarm counters and save serial number 	[0.1]
 Rectification bridge 0 = diodes         1 = semicontrolled	[0.1]
 Enable motor  thermal probe management (PT100/PTC/NTC)	[03]
 Enable smart brake	[0.1]
 Config. CAN Bus baud rate 0=1M1=800K2=500K3=250K4=125K5=50K6=20K7=10K	[07]
 Enable DC Injection 	[0,1]
 Enable motor flying restart 	[04]
 Enable open loop control	[0,1]
 Enable FIELD-BUS reference values	[0.1]
 Enable locked RUN	[0.1]
 Enable Energy Saving	[0.1]
 Choose value for current relay 0 = | I |/I NOM MOT 1= I  / I   NOM 2 = P / P NOM	[02]
 Type of overload 0=120% 30 ; 1=150%  30"; 2=200%  30 ; 3=200%  3 +155% 30 	[0 3]
 Enable radiator heat probe management (PTC/NTC) 	[0.1]
 Reset CAPTURE monitor	[0.1]
 NOT USED	[]
 Parameter bank active	[0.1]
 Read default parameters	[0.1]
 Read parameters from permanent memory	[0.1]
 Save parameters in permanent memory (FLASH)	[0.1]
 NOT USED	[]
 NOT USED	[]
 Intervention edge monitor TRIGGER 0 = up; 1 = down	[0.1]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 NOT USED	[]
 Enable bypass flux angle - frequency input	[0.1]
 Enable Braking Resistance Thermal Protection 	[0.1]
 Enable Safety STOP only like signaling	[0.1]